Safe clearances for your model were determined using a very specific and detailed u l.
Floor clearance wood stove.
Wood stove heat shields fire clearance distance reduction using heat shields how to install a wood stove or pellet stove heat shield.
We all want our wood stove installation to take up as little floor space as possible so the reduction of minimum clearances using special shields is common.
Clearances far stove and stovepipe from walls and floor.
The stove board was spaced 2 off of the floor 1 1 2 off of the wall and had several feet of clearance at either side and at the top so that air can circulate freely behind the board by convection.
Don t trust how to build heat shields for wood stoves.
Advertisement if your walls are combustible you can install a shield on a wall to reduce the stove s clearance area.
But cheating on clearances can create a very dangerous situation.
6 of air space between woodstove bottom and floor protection system.
We all want our wood stove installation to take up as little floor space as possible so the reduction of minimum clearances using special shields is common.
The common feature of the clearance reduction rules is the air space behind the shield material.
Using a piece of 24 gauge sheet metal installed on spacers 1 from an existing wall and floor will reduce stove clearances by 66 or from 36 to 12.
Canadian standards cited below recommend the following floor protection.
Clearances are measured from the outer surface of the appliance to the combustible material.
Does a stovepipe need special clearance to combustibles.
18 in front of the woodstove.
A clearance is the safe distance from the stove to a combustible surface.
Stovepipes like fireplaces wood burning stoves must be vented to the outside of the building.
These wall protection measurements can be reduced with the proper wall protection.
Some codes permit 12 clearance from the side of the wood stove to the edge of the floor protection.
Stove manufacturer s owners manuals should be checked for possible reductions.
Clearance should be three times the diameter of the pipe e g a 6 inch pipe needs 18 inches of clearance.
The clearances for un certified stoves can be reduced safely using the rules set out below.
Heat shields for clearance reduction adequate clearances are one of the two most important safety features of any wood stove installation.
Any area within 36 inches of the wood stove should be covered as shown in figure 2.
Other combustibles other combustible materials such as firewood paper curtains and plastics should be kept at least 36 inches from the stove.
The wood heat organization recommends setting the floor pad so that it s flush with the surrounding flooring you don t want to remove a fire hazard but create a tripping hazard.